欢迎光临TANEOR Compression Systems        English
-->
返回列表
您当前的位置:首页>>Service>>Case
TA-10/3 H2S gas
发表于:2026-08-23 分享至:

Main Unit

Ⅰ. Main Technical Parameters of Compressor

  1. Medium Composition: Hydrogen sulfide and other media

  2. Compressor Model: TA‑10/3

  3. Structure Type: Water‑cooled

  4. Compression Stages: Single‑stage compression

  5. Cylinder Bore of Each Stage (mm): 200

  6. Nominal Volume Flow (m³/min): 10

  7. Suction Pressure (MPa, Gauge): 0.03

  8. Discharge Pressure (MPa, Gauge): 0.3

  9. Suction Temperature (℃): ≤ 20

  10. Delivery‑gas Temperature (℃): Discharge ≤ 120; After cooling ≤ Cooling‑water temperature +15

  11. Compressor Rotational Speed (r/min): 550

  12. Transmission Mode: Belt drive

  13. Control Mode: Auto‑stop at set pressure; over‑pressure alarm and shutdown

  14. Lubrication Mode: Forced lubrication

  15. Installation Type: Electric stationary‑mounted

  16. Lubricating‑oil Consumption: Oil‑free cylinder, zero consumption

  17. Noise Level dB(A): ≤ 85

  18. Installed Motor Power: 55 kW / dIIBT4 / IP55

  19. Steel Skid‑mounted Chassis

  20. Overall Dimensions (L × W × H, mm): Approx. 2500 × 2000 × 2350

  21. Weight: Approx. 5000 kg

Auxiliary Equipment

Inlet filter, after‑water‑cooler, non‑return valve, safety valve, skid‑internal cooling‑water pipeline, skid‑internal gas pipeline, lubricating‑oil pipeline, instrument rack

Control System

PLC electrical control cabinet (non‑explosion‑proof type), local explosion‑proof operation column.

  1. The instrument panel is equipped with two‑stage pressure gauges and compressor oil‑temperature gauge.

  2. Automatic unloading when compressor reaches set pressure; automatic shutdown upon over‑pressure.

  3. Set‑point can be adjusted within rated pressure range according to user requirements.